Search Lights (Tech)Report
English:Search Lights (Tech) · Items & Equipment
Unlocks the searchlights mounted on gates and walls. It costs no money and no book; once the two earlier lighting techs are done, it takes about 4 hours at a Research Bench III or above.
A powerful searchlight for mounting on gates and walls. (In-game tech description, paraphrased)
This tech lets you mount searchlights on walls and gates. At night you cannot see well outside the walls; when a base wants to see farther, or keep the people on the wall from working in the dark, these lights do it. This light can only be fitted outdoors.
What it costs
This is the last stop of the lighting trilogy and the cheapest, because it charges no materials at all.
- There are two prerequisites: learn Internal Lighting (Tech) first, then Basic External Lighting (Tech). Each needs 1 Book.
- The searchlight research itself costs no money and no book.
- The bench must be tech level 3, i.e. Research Bench III or above, about 4 game hours on a single bench.
Once learned, building a searchlight takes 4 Iron Plates and 2 Electrical Components, and builds fast, three times quicker than ordinary buildings.
Compared with the spotlight
Basic External Lighting gives the spotlight, an ordinary light hung on a wall. The searchlight is the strengthened version of the same line, using twice the power and materials.
| Light | Tech | Power use | Build materials |
|---|---|---|---|
| Spotlight | Basic External Lighting | 4 | Iron Plates 2, Electrical Components 1 |
| Searchlight | Search Lights (Tech) | 8 | Iron Plates 4, Electrical Components 2 |
How far the light actually reaches, and how many extra cells of night vision it adds, is still unconfirmed, so don't treat it as a fixed guarantee.
Data and Formulas
Full numbers for players who want to dig deeper.
| Attribute | Value | Explanation |
|---|---|---|
| Category | Electrics | |
| Tech level | 3 | Required bench level |
| Research hours (time) | 8 | Internal hours |
| Research cost and materials | None | Cannot be researched repeatedly |
| Prerequisites | Basic External Lighting (level 2), Internal Lighting (level 1) |
Actual research time = 8 x 0.3 x 1.3^2 = about 4.06 world-clock hours (single bench, efficiency 1, default research speed for a new game).
The searchlight itself
| Attribute | Value | Notes |
|---|---|---|
| Building category | Light (LIGHTS) | Function is lighting, use range 40 |
| Power use (power output) | -8 | Negative means consumption; the spotlight is -4 |
| Build materials | Iron Plates x4, Electrical Components x2 | |
| Build speed mult | 3.0 | |
| Snaps to | Light mount nodes | Hung on wall or gate light mounts |
| Hardness | 30 |
Lighting buildings draw constant power indoors, and outdoors only when it is not daytime; outdoor lights in daytime draw no power and take no share of the power.
Research Notes
- The old draft gave the research time as 5 hours; converted from the game data it is about 4.06 world hours, and has been changed.
- The old draft said the searchlight has a larger lighting range than both the torch post and the lamp post, that one nearly covers a whole field, and that working in darkness slows efficiency. Neither point can be supported in the game data or the reverse-engineered data, and both were deleted.
- The old draft wrote the prerequisites as "Internal Lighting, Basic External Lighting"; the order now follows research level, internal first, then external.
- The old draft's data table entry "Cost: none" is correct.
- The rule that power is drawn only at night comes from the power-supply flow for lighting buildings. (kb:power-repair lighting section, kb:buildings 15 LIGHT, kb:economy F31)
Prerequisite techs
Basic External Lighting (Tech), Internal Lighting (Tech)
Related items
Village Types (Tech), Plate Armour Crafting (Tech), Robotics (Tech), Lamp Post Power (Tech), Imprisonment (Tech), Ore Drill (Tech), Drugs (Tech), Compound Walker (Tech)